Skip to Main Content View Text-Only

Portland Water Bureau

From forest to faucet, we deliver the best drinking water in the world.

GENERAL INFORMATION: 503-823-7404

1120 SW Fifth Ave, Suite 600, Portland, OR 97204

More Contact Info

Maps & Photos: Aerial & Street Level View of Proposed Work Areas

 
Click on the thumbnail image above to access an aerial map showing proposed work areas

During the proposed construction both inside the park and on the nearby street, the Portland Water Bureau and its contractor will work to protect trees and the reservoir and park facilities not impacted by the work. The work will be identified in eleven “Work Areas” (see area diagrams). Much of the new pipe installation will be conducted in a rolling work zone.  


Work Area 1

Connect pipe in SE Lincoln Street (outside park) to 42-inch diameter pipe outside the park (not part of the Land Use Review).

  

Work Area 2

Construct a 48-inch diameter pipe entering the park at SE Lincoln Street (outside park), crossing the field and NW corner of the dog park, and re-entering street at SE Lincoln Drive (inside park).

 

    

 

Work Area 3

Construct a 48-inch diameter pipe under SE Lincoln Drive (outside park) along with a vault with two (2) manholes in the roadway, and install two (2) small electrical conduits.

  

Work Area 4

Five (5) cut and plugs, make a 30-inch diameter pipe connection, and install two (2) small electrical conduits.

 

Work Area 5

Three (3) cut and plugs, install a 48-inch diameter pipe connecting two pipelines, removal of existing vault, and construction of a new aboveground vault.

   

 

Work Area 6

Two (2) cut and plugs, install an air vent, and potential installation of a backflow preventer.

 

Work Area 7

Three (3) cut and plugs and install a corrosion prevention system with aboveground cabinet, several small underground utility vaults, and electrical conduit.

 

Work Area 8

Two (2) cut and plugs on Reservoir 6 outlet pipes and the install of electrical cabinet. All work will occur adjacent to the SE 60th Avenue right-of-way.

 

Work Area 9

Cap pipe ends, cover weir opening, and add screens to pipes that will remain in use in Reservoir 1.

 

Work Area 10

Cap pipe ends and add screens to a weir and pipes that will remain in use in Reservoir 5.

 

Work Area 11

Install an emergency generator in the east side gatehouse and cap or screen pipe ends that will remain in use in Reservoir 6.

 


Work Area 1

Connect pipe in SE Lincoln Street (outside park) to 42-inch diameter pipe outside the park (not part of the Land Use Review).

Work Area 2

Construct a 48-inch diameter pipe entering the park at SE Lincoln Street (outside park), crossing the field and NW corner of the dog park, and re-entering street at SE Lincoln Drive (inside park).

Work Area 3

Construct a 48-inch diameter pipe under SE Lincoln Drive (outside park) along with a vault with two (2) manholes in the roadway, and install two (2) small electrical conduits.

Work Area 4

Five (5) cut and plugs, make a 30-inch diameter pipe connection, and install two (2) small electrical conduits.

Work Area 5

Three (3) cut and plugs, install a 48-inch diameter pipe connecting two pipelines, removal of existing vault, and construction of a new aboveground vault.

Work Area 6

Two (2) cut and plugs, install an air vent, and potential installation of a backflow preventer.

Work Area 7

Three (3) cut and plugs and install a corrosion prevention system with aboveground cabinet, several small underground utility vaults, and electrical conduit.

Work Area 8

Two (2) cut and plugs on Reservoir 6 outlet pipes and the install of electrical cabinet. All work will occur adjacent to the SE 60th Avenue right-of-way.

Work Area 9

Cap pipe ends, cover weir opening, and add screens to pipes that will remain in use in Reservoir 1.

Work Area 10

Cap pipe ends and add screens to a weir and pipes that will remain in use in Reservoir 5.

Work Area 11

Install an emergency generator in the east side gatehouse and cap or screen pipe ends that will remain in use in Reservoir 6.