Appeal 33468
Appeal Summary
Status: Hold for more information
Appeal ID: 33468
Submission Date: 9/10/24 1:27 PM
Hearing Date: 9/18/24
Case #: B-003
Appeal Type: Building
Project Type: commercial
Building/Business Name: Tesla
Appeal Involves: Alteration of an existing structure
Proposed use: Commercial Vehicle Repair
Project Address: 690 S Bancroft Street
Appellant Name: Dion Bruce
LUR or Permit Application #: Permit 23-106866-CO/23-106870-MT
Stories: 1 Occupancy: B/S1 Construction Type:
Fire Sprinklers: Yes -
Plans Examiner/Inspector: Kevin Wells
Plan Submitted Option: pdf [File 1]
Payment Option: electronic
Appeal Information Sheet
Appeal item 1
| Code Section | ASCE7-16,12.13.9 |
|---|---|
| Requires | Per the submitted Geotechnical report, vertical settlements in the range of 8 to 10 inches and lateral spreading between 4 and 17 feet with some portions of the property susceptible to flow failure. The estimated ground displacements exceed what is allowed by ASCE 7-16 12.13.9 for new structures supported on shallow foundations. |
| Code Modification or Alternate Requested | We're seeking to appeal the code to allow for the installation of the paint booth and shallow exhaust pit. The proposed paint booth is a lightweight low occupancy, specialty-use structure with a relatively low consequence of failure compared to other portions of the structure or comparatively sized new structures. We believe the code doesn't apply to our proposed paint booth. |
| Proposed Design | Our proposed paint booth design is constructed with light weight insulated panels anchored to existing slab. The proposed pits function as underground exhaust ducts to force the air down and vented through the exhaust ducts. See the attached drawings for reference. |
| Reason for alternative | It is our understanding that the installation of the paint booth does not contribute to the detriment any life safety concerns. |
Appeal Decision
Installation of a paint booth with a shallow pit that does not meet liquefication standards for foundations: Hold for more information.
PLEASE READ THE NOTE BELOW when providing Board requested Additional Information or when submitting a reconsideration after 1st time appeal Denial.
A reconsideration is required for submission online following the same submittal process and using the same appeals form as the original appeal. Indicate at the beginning of the appeal form that you are filing a reconsideration and include the original assigned Appeal ID number. The reconsideration will receive a new appeal number.
Include the original attachments and appeal language. Provide new text with only that information that is specific to the reconsideration in a separate paragraph(s) clearly identified as ""Reconsideration Text"" with any new attachments also referenced. Once submitted, the appeal cannot be revised.
No additional fee is required when the Board has requested additional information or for the first reconsideration of a denied appeal if submitted within 6 months of the original appeal. In these two specific instances please ignore the auto-generated request for another fee.
PLEASE NOTE that there will be no auto-generated verification that the appeal is successfully submitted. To verify this by viewing the submitted appeal, go to;