Appeal 33626
Appeal Summary
Status: HOLD FOR ADDITIONAL INFO
Appeal ID: 33626
Submission Date: 12/19/24 2:05 PM
Hearing Date: 1/8/25
Case #: R-001
Appeal Type: Building
Project Type: Residential
Building/Business Name: W+R Homeownership
Appeal Involves: Erection of a new structure
Proposed use: Townhomes
Project Address: N Knott and N Vancouver
Appellant Name: Jeff Stern
LUR or Permit Application #: LUR 24 -073629-LU
Stories: 3 Occupancy: R Construction Type: Residential
Fire Sprinklers: Yes - @ 4 two dwelling townhomes
Plans Examiner/Inspector: Jason Buerkle
Plan Submitted Option: pdf [File 1]
Payment Option: electronic
Appeal Information Sheet
Appeal item 1
| Code Section | Building Code Guide 19-11: Townhouses |
|---|---|
| Requires | Townhouse with ADU: One or more townhouses in a townhouse structure may be constructed as an attached two-family dwelling. The second dwelling is called an ADU. |
| Code Modification or Alternate Requested | This appeal is a terminology change request - to allow the ‘townhome with ADU’ design requirements to be used for the design of an ‘over/under two-family townhouse,’ per review under the Residential code. The reason for the modification to terminology is to allow the home type in the CM3 zone and allow for the townhome to be considered two dwelling units per zoning code. The ADU designation is not allowed in the CM3 zone. |
| Proposed Design | The townhomes were designed using the townhome code guide 19:11. The townhomes are not on their own lots, however, each has an implied property line and follows the requirements of R302.2 Townhouse separation wall assemblies. Specifically, using the modified two-hour wall assembly described in FIGURE R302.2.1(3). Additionally, the (4) over/under two-family dwellings are separated from each other by 1-hour horizontal and vertical assemblies. The over/under two-family dwellings are connected to each other with a convenience door, which is a 60-minute rated/listed door, and located in a true 1-hour wall assembly. Separate egress is provided from each unit. The convenience door is not require egress and is provided with a privacy hardware set. NFPA 13-D fire sprinklers will be installed throughout the over/under two-family townhomes. The design has been reviewed with the residential plans examiner and the fire marshall through a preliminary fire-life safety meeting. |
| Reason for alternative | The reason for the modification is because “ADUs" are not allowed in the CM3 zone. The design complies with townhome code requirements for a two-family dwelling. If this project were in a residential zone, it would be allowed as designed and without appeal. |
Appeal Decision
Allow two-family townhouses: Hold for additional information.
"Appellant has been sent an email clarifying the additional information requested. For information about how to file a reconsideration go to https://www.portland.gov/ppd/file-appeal/appeal-process or email PPDAppeals@portlandoregon.gov.
"