Appeal 34933
Appeal Summary
Status: DENIED
Appeal ID: 34933
Submission Date: 8/11/25 3:18 PM
Hearing Date: 8/21/25
Case #: 25-40
Appeal Type: Fire
Project Type: residential
Building/Business Name: Design by Faster Permits
Appeal Involves: Reconsideration of appeal 25-35/34894
Proposed use: Residential
Project Address: 1130 NE 106th Ave, Portland, OR
Appellant Name: Zac Horton
LUR or Permit Application #: Permit Permit 25-031440-RS
Stories: 1 Occupancy: R3 Construction Type: VB
Fire Sprinklers: No
Plans Examiner/Inspector: Dawn Krantz
Plan Submitted Option: pdf [File 1]
Payment Option: mail
Appeal Information Sheet
Appeal item 1
| Code Section | PFC B105.2 |
|---|---|
| Requires | The minimum fire flow and flow duration for one- and two-family dwellings having a fire-flow area that does not exceed 3,600 square feet shall be 1,000 gpm at 20 psi for 1 hour. For one and two-family dwellings exceeding 3,600 square feet, the required fire flow shall be as specified in PFC Appendix B, Table B105.1(1). |
| Code Modification or Alternate Requested | Fire flow reduction (without fire sprinklers) |
| Proposed Design | The available fire flow came in at 950 GPM. We're requesting a reduction in the allowed fire flow from 1000 GPM at 20psi for 1 hour to 950 GPM at 20psi for 1 hour. RECONSIDERATION TEXT: We will provide the following fire-resistive enhancements:
Equivalency Rationale: These materials significantly improve fire resistance and delay flame spread. Similar combinations have been accepted in appeals 31781, 31810, and 31823, resulting in board approvals for extended hose reach. |
| Reason for alternative | Fire sprinklers and installing a new fire hydrant are cost-prohibitive to the project and will likely result in the dwelling unit never being built. |
Appeal item 2
| Code Section | PFC 503.1.1 |
|---|---|
| Requires | The fire apparatus access road shall extend to within 150 feet of all portions of the facility and all portions of the exterior walls of the first story of the building as measured by an approved route around the exterior of the building. This distance can be increased to 250 feet if equipped throughout with approved automatic sprinkler systems installed in accordance with Section 903.3.1.1 or 903.3.1.2. Note on the plan set a DFS for 13D sprinkler system when applying this exception. |
| Code Modification or Alternate Requested | Increase in the access road distance from 150 feet to 180 feet per plan |
| Proposed Design | Increase in the access road distance from 150 feet to 180 feet without fire sprinklers. RECONSIDERATION TEXT: We will provide the following fire-resistive enhancements:
Equivalency Rationale: These materials significantly improve fire resistance and delay flame spread. Similar combinations have been accepted in appeals 31781, 31810, and 31823, resulting in board approvals for extended hose reach. |
| Reason for alternative | Fire sprinklers and installing a new fire hydrant are cost-prohibitive to the project and will likely result in the dwelling unit never being built. |
The administrative staff has not yet reviewed this appeal.